Skip to main navigation Skip to search Skip to main content

Maximal strength measurement: A critical evaluation of common methods—a narrative review

  • Konstantin Warneke
  • , Carl Maximilian Wagner
  • , Michael Keiner
  • , Martin Hillebrecht
  • , Stephan Schiemann
  • , David George Behm
  • , Sebastian Wallot
  • , Klaus Wirth
  • Leuphana University of Lüneburg
  • Memorial University of Newfoundland
  • University Of Health And Sport
  • University of Oldenburg

Research output: Contribution to journalReview articlepeer-review

Abstract

Measuring maximal strength (MSt) is a very common performance diagnoses, especially in elite and competitive sports. The most popular procedure in test batteries is to test the one repetition maximum (1RM). Since testing maximum dynamic strength is very time consuming, it often suggested to use isometric testing conditions instead. This suggestion is based on the assumption that the high Pearson correlation coefficients of r ≥ 0.7 between isometric and dynamic conditions indicate that both tests would provide similar measures of MSt. However, calculating r provides information about the relationship between two parameters, but does not provide any statement about the agreement or concordance of two testing procedures. Hence, to assess replaceability, the concordance correlation coefficient (ρc) and the Bland-Altman analysis including the mean absolute error (MAE) and the mean absolute percentage error (MAPE) seem to be more appropriate. Therefore, an exemplary model based on r = 0.55 showed ρc = 0.53, A MAE of 413.58 N and a MAPE = 23.6% with a range of −1,000–800 N within 95% Confidence interval (95%CI), while r = 0.7 and 0.92 showed ρc = 0.68 with a MAE = 304.51N/MAPE = 17.4% with a range of −750 N–600 N within a 95% CI and ρc = 0.9 with a MAE = 139.99/MAPE = 7.1% with a range of −200–450 N within a 95% CI, respectively. This model illustrates the limited validity of correlation coefficients to evaluate the replaceability of two testing procedures. Interpretation and classification of ρc, MAE and MAPE seem to depend on expected changes of the measured parameter. A MAPE of about 17% between two testing procedures can be assumed to be intolerably high.
Original languageEnglish
Article number1105201
Pages (from-to)1105201
JournalFrontiers in Sports and Active Living
Volume5
DOIs
Publication statusPublished - 17 Feb 2023

Keywords

  • 1RM
  • agreement
  • dynamic
  • isometric
  • isometric mid thigh pull
  • maximal strength testing
  • performance testing
  • squat

Fingerprint

Dive into the research topics of 'Maximal strength measurement: A critical evaluation of common methods—a narrative review'. Together they form a unique fingerprint.

Cite this