Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Maximal strength measurement: A critical evaluation of common methods—a narrative review

  • Konstantin Warneke
  • , Carl Maximilian Wagner
  • , Michael Keiner
  • , Martin Hillebrecht
  • , Stephan Schiemann
  • , David George Behm
  • , Sebastian Wallot
  • , Klaus Wirth
  • Leuphana University of Lüneburg
  • Memorial University of Newfoundland
  • University Of Health And Sport
  • University of Oldenburg

Publikation: Beitrag in FachzeitschriftÜbersichtsartikelpeer-review

Abstract

Measuring maximal strength (MSt) is a very common performance diagnoses, especially in elite and competitive sports. The most popular procedure in test batteries is to test the one repetition maximum (1RM). Since testing maximum dynamic strength is very time consuming, it often suggested to use isometric testing conditions instead. This suggestion is based on the assumption that the high Pearson correlation coefficients of r ≥ 0.7 between isometric and dynamic conditions indicate that both tests would provide similar measures of MSt. However, calculating r provides information about the relationship between two parameters, but does not provide any statement about the agreement or concordance of two testing procedures. Hence, to assess replaceability, the concordance correlation coefficient (ρc) and the Bland-Altman analysis including the mean absolute error (MAE) and the mean absolute percentage error (MAPE) seem to be more appropriate. Therefore, an exemplary model based on r = 0.55 showed ρc = 0.53, A MAE of 413.58 N and a MAPE = 23.6% with a range of −1,000–800 N within 95% Confidence interval (95%CI), while r = 0.7 and 0.92 showed ρc = 0.68 with a MAE = 304.51N/MAPE = 17.4% with a range of −750 N–600 N within a 95% CI and ρc = 0.9 with a MAE = 139.99/MAPE = 7.1% with a range of −200–450 N within a 95% CI, respectively. This model illustrates the limited validity of correlation coefficients to evaluate the replaceability of two testing procedures. Interpretation and classification of ρc, MAE and MAPE seem to depend on expected changes of the measured parameter. A MAPE of about 17% between two testing procedures can be assumed to be intolerably high.
OriginalspracheEnglisch
Aufsatznummer1105201
Seiten (von - bis)1105201
FachzeitschriftFrontiers in Sports and Active Living
Jahrgang5
DOIs
PublikationsstatusVeröffentlicht - 17 Feb. 2023

Fingerprint

Untersuchen Sie die Forschungsthemen von „Maximal strength measurement: A critical evaluation of common methods—a narrative review“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren